Hafler DH-200 User Manual Page 12

  • Download
  • Add to my manuals
  • Print
  • Page
    / 21
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 11
The power transformer supplied in
DH-220
amplifiers sold in
the
lJSA
is intended for 120 volt, 60 Hz operation only. For use
in other countries, a multi-voltage transformer is available at
higher cost. It has dual tapped primary windings which can be
arranged in various series-parallel combinations for 100,
110,
120,
200,
220 and 240 volt
50
or 60 cycle AC mains. The
schematic diagram details the wiring combinations which are
represented
pictorially here.
Note that a separate 2-lug terminal strip is required when the
multi-voltage
transformer is used. This is supplied in kits which
include the special transformer. If the amplifier is operated with
200
to 240 volt tines, the 7 amp line fuse which is supplied should
be replaced with a 4 amp
Slo-Blo
type fuse.
n
VOLTAGE CHART
measured
with 120 volt line, no signal. with respect to the ground buss between the two capacitors in the power supply.
E
B
c
E
B
c
s
G
D
Ql
62.6
62.1)
0.88
Q8
63.0 62.0
1.54 Q401
0
1.0
65.4
Q2
-62.6 -62.0 -0.37
Q9
-1.27 -0.6
1.54
Q402
0 1.0
65.4
Q3
-0.32
0.22
61.8
QlO
-63.0 -62.0
0
Q403
0
-0.8 -65.4
Q4
-0.32
0.22 61.8
Q11
-63.0 -62.0 -1.35 Q404
0
-0.8 -65.4
Q5
0.8 0.22
-62.0
Ql2
1.0
1.54
65.0
Q6
0.8 0.22
-62.0
Q13
-0.8 -1.35 -65.0
Q7
63.0
62.0 0
12